Steel sheet piles SCH3-700 SCH4-700 and SCH5-750 shall ensure that the following requirements are established according to the control requirements of Baer Bay and Melbourne. The connection between soil reinforcement and MSE wall panel components should meet the following minimum standards. The filling material you choose will be affected by multiple SCH3-700 factors, including the characteristics of the surrounding area, the possibility of water penetration into the wall, the physical structure of the wall, sheet piling for sale and the material behind the wall.


The control area should start at least 6 feet from the front to prevent employees from being exposed to falling or restricted protection systems. The tensile resistance capacity should be at least 2 times the allowable force of the design SCH4-700, and the connection force of the total force of the reinforced bar should not exceed 0.75 inches. We should use the best available material, Baer Bay, and remember that the soil in the box is the retaining wall.


The cold rolled steel sheet pile SCH 3-700 or SCH 4-700 or SCH 5-750 should be separated from other work areas by establishing a warning line. Connections shall be directly connected to all anti longitudinal tensile elements reinforced by soil. Besides enough foundation, the selection of backfill material is the most important factor that influences the final performance of the wall. Warning SCH5-750 line shall consist of wires, cables or chains supported by strut. When friction depends on constant gravity, the connection should not depend on the frictional resistance of Melbourne. Relatively clean bank grit or crusher grinder is usually suitable.


Section Dimensions Sectional Area Mass Moment of inertia Modulus of section


Width Height Thickness Pile Wall



B H t





mm mm mm cm2/m kg/m kg/m2 cm4/m cm3/m
SCH3-700 700 146 4 56 30.8 44 1945 265
SCH4-700 700 148 6 84.3 46.2 66 3080 410
SCH5-750 750 250 4 63.6 37.4 49.9 6535 511
SCH6-750 750 251 5 79.2 46.6 62.2 8142 632
SCH7-750 750 252 6 94.68 55.7 74.3 9732 750
SCH10-750 750 253 7 116.6 68.6 91.5 11880 956
SCH11-750 750 254 8 133.5 78.6 104.8 13586 1093


CONTACT US TODAY!

Contact with us

Shunli Steel Group
Tel: 0086 -25 - 84722733
Fax: 0086 - 25 - 84730966
Hand phone: 0086 -13739192886;
001-9023936528(Canada & USA)

QQ: 236979001
E-mail: admin@shunlisteel.cn

Get in touch

CONTACT US TODAY!

Sheet piling for sale     About Us      Products       Technical Libirary       Certificates      Facilities       Contact Us
Copyright 2015 Shunli Cold-formed Steel Industrial Co., Ltd. All rights reserved  sheet piling prices