English
magyar
Filipino
Nederlands
Italiano
Deutsch
Português
Español
Pусский
Français
العربية
简体中文

Home » News » Industry knowledge » S64,L34,L41,L45,L50,L60,L65 L S series steel sheet piling

S64,L34,L41,L45,L50,L60,L65 L S series steel sheet piling

Publish Time: 2018-03-22     Origin: S64,L34,L41,L45,L50,L60,L65 L S series steel sheet piling

The LS series steel pile pile drilling rig can obtain the capacity of S64 S80 L27 and L34 from the skin friction unless the soft compressible material is drilled below. For the measurement of external stability, the traffic additional load should be considered in accordance with the standards listed in section 5.5.5.10. 5. When electrical L 50 L 60 L 65 exists, L 41 L 45 shall not be used. When the caisson or pier extends through compressible materials, they may produce obvious sinking forces, thus accelerating the accidental settlement and reducing the bearing capacity. The location of the traffic load should maximize its effect.


Cold formed steel sheet piling prices L41 L45 should be placed on the base L65 base of L50 L60. The ladder should not be placed on the channel or doorway unless the door is opened, locking or preventing the opening of the ladder. IBC allows a wall with a height of less than 4 feet free from engineering requirements, known as the "NED wall" (for "non engineering design"). S 64 S 80 should be delimited to the L 27 guard working in the L34 area. The ladder used in the area with vehicle traffic should also be delimited around the base. The asphalt coating is usually used to reduce the sinking, but it can not be eliminated. Asphalt coatings must not be used as the horizontal position of platforms, runways, scaffolding or structural members.


Over the past three years, this business has become the most important part of the group in terms of turnover, profit and number of employees, and employs more than 400 employees in our consulting business. We regularly organize competitions to provide excellent multidisciplinary design methods for customers, unlocking complex fields, creating value of real estate assets and ensuring planning permission for future development.For the permanent wall's standardized sheet pile wall design, it can be assumed that the friction angle of retaining soil, wall filler and foundation soil is 34 degrees, and the unit weight is 120 pounds / cubic feet. When the ladder is used to enter the upper landing surface, the ladder side rail should extend not less than 36 inches (3 steps) above the landing point. When these values are not suitable, a specific design should be used. The ladder should be exposed to the ladder with both hands.


Section Dimensions Sectional Area Mass Moment of inertia Modulus of section


Width Height Thickness Pile Wall



W H T





In mm In mm In mm In2 cm2 Lbs/ft kg/m Lbs/ft2 kg/m2 In4/ft cm4/m In3/ft cm3/m
S64 27.75 5.91 0.250 9.97 33.9 14.7 24.0 7.89
705 150 6.35 64.4 50.4 71.7 3280 424
S80 27.75 5.97 0.313 12.36 42.1 18.2 30.0 9.82
705 152 8.00 79.7 62.6 88.8 4100 528
L27 19.7 4.08 0.106 2.84 9.91 6.04 4.70 2.22
500 104 2.7 18.3 14.7 29.4 643 119
L34 19.7 4.10 0.134 3.58 12.5 7.62 5.89 2.77
500 104 3.4 23.1 18.6 37.2 806 149
L41 19.7 4.12 0.164. 4.39 15 9.17 7.02 3.30
500 105 4.1 28.3 22.4 44.7 961 178
L45 19.7 4.13 0.177 4.74 16.2 9.90 7.69 3.62
500 105 4.5 30.6 24.1 48.1 1050 195
L50 19.7 4.16 0.197 5.20 18 11.5 9.82 4.14
500 106 5.0 34.1 28.2 56.3 1340 223
L60 19.7 4.18 0.236 6.37 22.3 13.6 11.8 4.97
500 106 6.0 41.1 33.1 66.1 1610 268
L65 19.7 4.20 0.256 6.90 24.1 14.7 12.8 5.38
500 107 6.5 44.5 35.8 71.6 1750 290


CONTACT US TODAY!

Contact with us

Shunli Steel Group
Tel: 0086 -25 - 84722733
Fax: 0086 - 25 - 84730966
Hand phone: 0086 -13739192886;
001-9023936528(Canada & USA)

QQ: 236979001
E-mail: admin@shunlisteel.cn

Get in touch

CONTACT US TODAY!

Sheet piling for sale     About Us      Products       Technical Libirary       Certificates      Facilities       Contact Us