The cross section of the middle light thin slice. The wire rope used for a scaffold should be able to support six times the predetermined load of the MSZ15-350. Bank or sheet piles suppliers sloping scaffolding is prohibited. All joints in the film should be welded to prevent leakage. Bin fill should be 8 inches thick loose elevator and the maximum MSZ15-340 shall be compacted to 95% Procter standard gauge density.Narrow support (30 inches wide). No working platform should be erected above 4 feet unless equipped with extension support. It is not allowed to pass through saturated compaction.


Contrary to popular believe, Cold Formed Sheet Piles to give very respectable water tightness. Though in most cases, water conductivity in Hot Rolled Sheet Piles are still lower than Cold Formed Sheet Piles, Mer Lion Metals can always supply piles with waterproofing membrane pre-injected in the factory without the hassle of it being done on site. This membrane is called Wadit and it is by far the most superior type of waterproofing method made specifically for the sheet piling market.


Zee Mega 15 steel sheet pile shall be placed MSZ15-375 and MSZ15-406 thick loose lifts and compacted to the maximum stress standard Procter minimum 90% density.Scaffolds should be supported, and support appropriate length, making the scaffold will keep vertical and rigid. All of the listed medium MSZ15-312 lightweight sheet piles are fully manufactured in the United States. All middle light sheet piling can be cut to the length you need.


The linked sheet pile MSZ15-312 MSZ15-340 is not big enough to be labeled MSZ15-350, with the danger of waterproof sealant word "hole" or "cover", it should be marked with high visibility paint warning recognition. If MSZ15-406 is required to remove the cover, the display will remain at the opening until the cover is replaced. The surveyor should recommend persons entering the dangerous area to prevent exposure to dangerous areas, but not to carry out other tasks.


Sectio Dimensio Ma Moment of inertia Modulus of sectio



Width Height Thickne Pile Wall


w h t/




I I I Lbs/ft Lbs/ft2 In4/ft In3/ft
MSZ10-312 38.82 2.19 0.312 49.72 15.37 1.3 0.67
MSZ10-340 38.82 2.19 0.340 54.10 16.72 1.41 0.72
MSZ10-350 38.82 2.19 0.350 55.69 17.22 1.45 0.74
MSZ10-375 38.82 2.19 0.373 59.67 18.45 1.56 0.79
MSZ10-406 38.82 2.19 0.406 64.60 19.97 1.73 0.86
MSZ11-312 38.55 3.53 0.312 49.72 15.48 6.83 3.76
MSZ11-340 38.55 3.53 0.340 54.1 16.84 7.43 4.06
MSZ11-350 38.55 3.53 0.350 55.69 17.34 7.65 4.17
MSZ11-375 38.55 3.53 0.375 59.67 18.58 8.21 4.44
MSZ11-406 38.55 3.53 0.406 64.6 20.11 8.92 4.79
MSZ12-312 37.72 6.64 0.312 49.72 8.76 29.29 8.76
MSZ12-340 37.72 6.64 0.340 54.1 9.50 31.87 9.50
MSZ12-350 37.72 6.64 0.350 55.69 9.77 32.84 9.77
MSZ12-375 37.72 6.64 0.375 59.67 10.43 35.17 10.43
MSZ12-406 37.72 6.64 0.406 64.6 11.27 38.16 11.27
MSZ13-312 36.38 9.58 0.312 49.72 14.13 67.86 14.13
MSZ13-340 36.38 9.58 0.340 54.10 15.32 73.79 15.32
MSZ13-350 36.38 9.58 0.350 55.69 15.74 75.93 15.74
MSZ13-375 36.38 9.58 0.375 50.67 16.81 81.34 16.81
MSZ13-406 36.38 9.58 0.406 64.6 18.18 88.27 18.18
MSZ14-312 34.56 12.24 0.312 12.27 19.62 120.97 19.62
MSZ14-340 34.56 12.24 0.340 18.89 21.29 131.28 21.29
MSZ14-350 34.56 12.24 0.350 19.34 21.91 135.50 21.91
MSZ14-375 34.56 12.24 0.375 20.72 23.38 144.93 23.38
MSZ14-406 34.56 12.24 0.406 22.43 25.29 157.25 25.29
MSZ15-312 32.79 14.11 0.312 49.72 18.20 172.66 24.24
MSZ15-340 32.79 14.11 0.340 54.10 19.80 187.52 26.27
MSZ15-350 32.79 14.11 0.350 55.69 20.38 193.26 27.06
MSZ15-375 32.79 14.11 0.375 59.67 21.84 207.03 28.91
MSZ15-406 32.79 14.11 0.406 64.60 23.64 224.46 31.27
MSZ16-312 31.05 15.54 0.312 49.72 19.22 223.36 28.45
MSZ16-340 31.05 15.54 0.340 54.10 20.91 242.98 30.88
MSZ16-350 31.05 15.54 0.350 55.69 21.53 249.85 31.74
MSZ16-375 31.05 15.54 0.375 59.67 23.06 267.87 33.95
MSZ16-406 31.05 15.54 0.406 64.60 24.97 290.74 36.75
MSZ17-312 29.71 16.43 0.312 49.72 20.09 262.34 31.60
MSZ17-340 29.71 16.43 0.340 54.1 21.86 285.10 34.27
MSZ17-350 29.71 16.43 0.350 55.69 22.50 293.36 35.25
MSZ17-575 29.71 16.43 0.375 59.67 24.11 314.57 37.71
MSZ17-406 29.71 16.43 0.406 64.60 26.10 241.03 40.80
MSZ18-312 28.38 17.2 0.312 49.73 20.58 296.05 34.49
MSZ18-340 28.38 17.2 0.24 54.1 22.39 322.09 37.45
MSZ18-350 28.38 17.2 0.350 55.69 23.04 330.95 38.46
MSZ18-375 28.38 17.2 0.375 59.67 24.69 354.49 41.12
MSZ18-406 28.38 17.2 0.406 64.6 26.74 384.83 44.53
MSZ19-340 26.88 17.9 0.340 54.1 23.61 368.18 41.17
MSZ19-350 26.88 17.9 0.350 55.69 24.30 867.04 42.24
MSZ19-375 26.88 17.9 0.375 59.67 26.04 929.74 45.25
MSZ19-406 26.88 17.9 0.406 64.60 28.19 1008.15 48.97


CONTACT US TODAY!

Contact with us

Shunli Steel Group
Tel: 0086 -25 - 84722733
Fax: 0086 - 25 - 84730966
Hand phone: 0086 -13739192886;
001-9023936528(Canada & USA)

QQ: 236979001
E-mail: admin@shunlisteel.cn

Get in touch

CONTACT US TODAY!

Sheet piling for sale     About Us      Products       Technical Libirary       Certificates      Facilities       Contact Us
Copyright 2015 Shunli Cold-formed Steel Industrial Co., Ltd. All rights reserved  sheet piling prices